{"product_id":"kove-core-0-5hp-ice-bath-chiller-cooling-system-temperature-controlled-695w","title":"KOVE Core 0.5HP Ice Bath Chiller – Cooling System - Temperature Controlled - 695W","description":"\u003cdiv class=\"product-intro\"\u003e\n\u003ch2\u003eConsistent Cold Plunge Temperatures — Without Daily Ice Runs\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKOVE Core Ice Bath Chiller – 0.5HP (695W)\u003c\/strong\u003e is a compact, cooling-only unit built for repeatable cold exposure at home or in light commercial settings. It’s designed to keep cold plunging realistic long-term: stable temperatures, straightforward setup, and filtration that protects the system during regular use.\u003c\/p\u003e\n\u003cp\u003eAvailable in \u003cstrong\u003eMatt White\u003c\/strong\u003e and \u003cstrong\u003eDeep Black\u003c\/strong\u003e, with a clean, minimal form factor that suits both indoor setups and smaller UK outdoor spaces.\u003c\/p\u003e\n\u003ch2\u003eCooling Performance \u0026amp; Electrical Specs\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling power:\u003c\/strong\u003e 1200W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCools to:\u003c\/strong\u003e 3°C\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput power:\u003c\/strong\u003e 695W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor power:\u003c\/strong\u003e 410W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent:\u003c\/strong\u003e 3.2A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e 220–240V, 50Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsage environment:\u003c\/strong\u003e 2–45°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHose length: \u003c\/strong\u003e1.7m\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower cable length:\u003c\/strong\u003e 2.3m\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFiltration Built for Regular Use (Not Just a Basic Strainer)\u003c\/h2\u003e\n\u003cp\u003eWater quality matters — not only for cleanliness, but for protecting the pump and internal components. Many cheaper chillers rely on a basic mesh strainer only. KOVE takes a more practical approach for repeatable use.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHair filter\u003c\/strong\u003e (coarse pre-filter)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal inline filter system\u003c\/strong\u003e with a \u003cstrong\u003e5-inch filter bottle housing\u003c\/strong\u003e and a 5\u003cstrong\u003e-micron cartridge\u003c\/strong\u003e for finer debris capture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis two-stage approach helps keep water clearer and helps reduce pump strain over time — especially useful if you’re plunging several times per week.\u003c\/p\u003e\n\u003ch2\u003eCompatibility \u0026amp; Connections\u003c\/h2\u003e\n\u003cp\u003eThe chiller uses \u003cstrong\u003estandard 1\/2-inch connections\u003c\/strong\u003e — the common connector size for quality ice bath systems. It pairs perfectly with \u003cstrong\u003eall KOVE ice baths\u003c\/strong\u003e, and is also broadly compatible with other ice baths that use standard 1\/2-inch fittings.\u003c\/p\u003e\n\u003ch2\u003eReal-World Water Volume (Why “400L Ice Bath” Doesn’t Mean 400L of Water)\u003c\/h2\u003e\n\u003cp\u003eMost ice bath capacity figures are based on the tub’s total volume. In practice, \u003cstrong\u003ewater volume is usually far lower\u003c\/strong\u003e, because bodies displace water and tubs aren’t filled to the brim. This is why a chiller rated for \u003cstrong\u003e200–300L\u003c\/strong\u003e often performs well with many “400L” tubs in real use.\u003c\/p\u003e\n\u003cp\u003eIn practical terms, the 0.5HP unit is best suited to \u003cstrong\u003etypical water volumes of 200–300L\u003c\/strong\u003e, and is a strong match for most inflatable and compact cold plunge tubs — including many tubs marketed as “up to 400L”.\u003c\/p\u003e\n\u003ch2\u003eSize, Weight \u0026amp; Placement\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 375 × 300 × 345 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 22.2 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor best performance, place the unit on a stable surface with sensible airflow and allow clearance around vents. Avoid positioning where water can pool underneath.\u003c\/p\u003e\n\u003ch2\u003eKOVE vs Cheaper Chillers (What Usually Changes at Lower Price Points)\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; border-bottom: 1px solid rgba(0,0,0,0.15); padding: 10px 8px;\"\u003eCategory\u003c\/th\u003e\n\u003cth style=\"text-align: left; border-bottom: 1px solid rgba(0,0,0,0.15); padding: 10px 8px;\"\u003eKOVE 0.5HP\u003c\/th\u003e\n\u003cth style=\"text-align: left; border-bottom: 1px solid rgba(0,0,0,0.15); padding: 10px 8px;\"\u003eTypical Cheaper Units\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 8px; border-bottom: 1px solid rgba(0,0,0,0.08);\"\u003eFiltration\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 8px; border-bottom: 1px solid rgba(0,0,0,0.08);\"\u003eHair filter + external 5\" housing + 5-micron cartridge\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 8px; border-bottom: 1px solid rgba(0,0,0,0.08);\"\u003eOften mesh-only or minimal filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 8px; border-bottom: 1px solid rgba(0,0,0,0.08);\"\u003eCompatibility\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 8px; border-bottom: 1px solid rgba(0,0,0,0.08);\"\u003eStandard 1\/2\" connections\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 8px; border-bottom: 1px solid rgba(0,0,0,0.08);\"\u003eSometimes non-standard fittings or unclear specs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 8px; border-bottom: 1px solid rgba(0,0,0,0.08);\"\u003eReal-world sizing\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 8px; border-bottom: 1px solid rgba(0,0,0,0.08);\"\u003eSpecced for ice bath water volumes, not inflated marketing numbers\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 8px; border-bottom: 1px solid rgba(0,0,0,0.08);\"\u003eOften optimistic capacity claims\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 8px;\"\u003eOwnership\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 8px;\"\u003eDesigned for repeatable use + easy integration\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 8px;\"\u003eMore variables, more guesswork\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eBundle Recommendation (Most Popular Setup)\u003c\/h2\u003e\n\u003cp\u003eThe simplest long-term setup is a \u003cstrong\u003eKOVE Ice Bath + KOVE Chiller\u003c\/strong\u003e. You get standardised connections, correct flow expectations, and a system designed to work together from day one.\u003c\/p\u003e\n\u003cp\u003eIf you already have an ice bath: as long as it uses \u003cstrong\u003estandard 1\/2-inch fittings\u003c\/strong\u003e, this chiller will integrate cleanly.\u003c\/p\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWill this chiller work with a “400L” ice bath?\u003c\/strong\u003e\u003cbr\u003eOften, yes. Most “400L” tubs do not contain 400L of water in real use. Typical water volume is commonly closer to 200–300L once filled to a sensible level and used by a person.\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eIs This Chiller Suitable for Commercial Use?\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eKOVE chillers can be suitable for \u003cspan class=\"s1\"\u003e\u003cb\u003eshared use\u003c\/b\u003e\u003c\/span\u003e, including gyms, studios, wellness centres and other environments where multiple users are plunging throughout the day, provided the correct model is selected and appropriate maintenance is carried out.\u003c\/p\u003e\n\u003cp class=\"p3\"\u003eHigher usage places significantly greater demands on the filtration system. As a minimum:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe secondary hair net filter should be inspected and cleaned \u003cspan class=\"s1\"\u003e\u003cb\u003edaily\u003c\/b\u003e\u003c\/span\u003e, or more frequently where required.\u003c\/li\u003e\n\u003cli\u003eThe primary filter cartridge should be inspected regularly and replaced whenever water flow becomes restricted or in accordance with the maintenance schedule.\u003c\/li\u003e\n\u003cli\u003eWater chemistry should be monitored and maintained to help protect the chiller and ensure water quality.\u003c\/li\u003e\n\u003cli\u003eAdequate water flow and ventilation must be maintained at all times.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p2\"\u003eFailure to maintain the filtration system can restrict water flow, potentially leading to reduced performance or damage to internal components. \u003c\/p\u003e\n\u003cp class=\"p2\"\u003eNot every KOVE chiller is designed for every commercial application. Factors such as plunge size, water volume, ambient temperature, user frequency and operating hours all influence the appropriate specification. Call us for more advice.\u003c\/p\u003e\n\u003cp\u003e\u003cb style=\"font-size: 0.875rem;\"\u003eIf you are purchasing a chiller for commercial or shared use, we strongly recommend contacting the KOVE team before ordering.\u003c\/b\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e We’ll be happy to discuss your setup and recommend the most suitable product.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"p4\"\u003eWhere a product is used in an environment or application for which it is not designed, or against KOVE’s recommendation, warranty coverage may be limited or declined where the misuse contributes to the fault.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat’s the difference between the hair filter and the 20-micron filter?\u003c\/strong\u003e\u003cbr\u003eThe hair filter catches larger debris first. The \u003cstrong\u003e20-micron cartridge\u003c\/strong\u003e then captures finer particulate before it reaches the system, improving water clarity and helping protect internal components. As with all ice bath chillers, in light commercial environments the hair net filter will need daily changing to avoid damage to the internals. The 5 inch filter will also need frequent changes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this heating + cooling?\u003c\/strong\u003e\u003cbr\u003eNo — this model is \u003cstrong\u003ecooling only\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it UK compatible?\u003c\/strong\u003e\u003cbr\u003eYes — \u003cstrong\u003e220–240V, 50Hz\u003c\/strong\u003e. Just plug it in.\u003c\/p\u003e\n\u003ch2\u003eWhy Choose KOVE?\u003c\/h2\u003e\n\u003cp\u003eKOVE focuses on equipment that holds up to repeat use: sensible specs, straightforward compatibility, and practical ownership. The goal is a chiller you can rely on week after week — without complication.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Kove","offers":[{"title":"Deep Black","offer_id":54833097965897,"sku":"KOVE-IC-CB","price":599.0,"currency_code":"GBP","in_stock":true},{"title":"Matt White","offer_id":54833097998665,"sku":"KOVE-IC-CW","price":599.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1016\/4830\/2409\/files\/0.5_black_1.png?v=1783686399","url":"https:\/\/www.homeandgardenstore.co.uk\/products\/kove-core-0-5hp-ice-bath-chiller-cooling-system-temperature-controlled-695w","provider":"Home and Garden Store UK","version":"1.0","type":"link"}